Home » Saltwater Aquarium

Programming Your AquaController Jr. – Neptune

6 October 2009 No Comment

ACJr_BlueLED[1]
Neptune Systems Aqua Controller Jr: This is one item that has saved me numerous times from overheating.

 

Here is my program for my ACJR:

  • MHL-A01; // 250W Metal Halide Left
  • MHR-A02; // 250W Metal Halide Right
  • ML-A03; // Seio 820 Left
  • PMR-A04; // Seio 820 Right
  • SKM-A05; // Vertex IN-180 Skimmer
  • HTR-A06; // Heater
  • FNC-A07; // Fan Canopy
  • RTN-A08; // Mag 7 Return

 

 Turn on SKM and Display Pumps at startup

  • If Time > 00:00 Then SKM ON
  • If Time > 00:00 Then PML ON
  • If Time > 00:00 Then PMR ON

 

Turn on Left Halide at 5pm and off at 11pm

  • If Time > 17:00 Then MHL ON
  • If Time > 23:00 Then MHL OFF

 

Turn on Right Halide at 5pm and off at 11pm

  • If Time > 17:00 Then MHR ON
  • If Time > 23:00 Then MHR OFF

Control Temperature

  • If Temp < 78.0 Then HTR ON
  • If Temp > 78.0 Then HTR OFF

Manage Fans

  • If Temp > 80.0 Then FNC ON
  • If Temp < 78.5 Then FNC OFF

High Temp Shutoff

  • If Temp > 83.0 Then MHL OFF
  • If Temp > 83.0 Then MHR OFF
  • If Temp > 84.5 Then SKM OFF
  • Max Change 045 M Then MHL OFF
  • Max Change 045 M Then MHR OFF

Feed Mode, shut off seios and SKM, after 15 minutes (feed interval) turn on seios, SKM stays off an extra 10 minutes.

  • If Feed cycle Then PML OFF
  • If Feed cycle Then PMR OFF
  • If Feed cycle Then SKM OFF
  • Max Change 025 M Then SKM OFF

Leave your response!

Add your comment below, or trackback from your own site. You can also subscribe to these comments via RSS.

Be nice. Keep it clean. Stay on topic. No spam.

You can use these tags:
<a href="" title="" rel=""> <abbr title=""> <acronym title=""> <b> <blockquote cite=""> <cite> <code> <del datetime=""> <em> <i> <q cite=""> <strike> <strong>

This is a Gravatar-enabled weblog. To get your own globally-recognized-avatar, please register at Gravatar.