Programming Your AquaController Jr. – Neptune
![ACJr_BlueLED[1] ACJr_BlueLED[1]](http://tylermerrick.com/blog/wp-content/uploads/2009/10/ACJr_BlueLED1.gif)
Neptune Systems Aqua Controller Jr: This is one item that has saved me numerous times from overheating.
Here is my program for my ACJR:
- MHL-A01; // 250W Metal Halide Left
- MHR-A02; // 250W Metal Halide Right
- ML-A03; // Seio 820 Left
- PMR-A04; // Seio 820 Right
- SKM-A05; // Vertex IN-180 Skimmer
- HTR-A06; // Heater
- FNC-A07; // Fan Canopy
- RTN-A08; // Mag 7 Return
Turn on SKM and Display Pumps at startup
- If Time > 00:00 Then SKM ON
- If Time > 00:00 Then PML ON
- If Time > 00:00 Then PMR ON
Turn on Left Halide at 5pm and off at 11pm
- If Time > 17:00 Then MHL ON
- If Time > 23:00 Then MHL OFF
Turn on Right Halide at 5pm and off at 11pm
- If Time > 17:00 Then MHR ON
- If Time > 23:00 Then MHR OFF
Control Temperature
- If Temp < 78.0 Then HTR ON
- If Temp > 78.0 Then HTR OFF
Manage Fans
- If Temp > 80.0 Then FNC ON
- If Temp < 78.5 Then FNC OFF
High Temp Shutoff
- If Temp > 83.0 Then MHL OFF
- If Temp > 83.0 Then MHR OFF
- If Temp > 84.5 Then SKM OFF
- Max Change 045 M Then MHL OFF
- Max Change 045 M Then MHR OFF
Feed Mode, shut off seios and SKM, after 15 minutes (feed interval) turn on seios, SKM stays off an extra 10 minutes.
- If Feed cycle Then PML OFF
- If Feed cycle Then PMR OFF
- If Feed cycle Then SKM OFF
- Max Change 025 M Then SKM OFF